How to programme IP Phones for use on CS5000 (Inter-tel / Mitel)

To programme IP Phones for remote users

(ALL EXAMPLE IPs ARE HIGHLIGHTED IN RED)

 

To programme the phones simply hold down keys 7 and 8 as the phone powers up. This will provide you with the screen to program them. Use the “Outbound key” (bottom right hand corner) to skip through the options. Use the “forward” key to jump between field items. i.e to enter 10.0.0.20 do the following :

 

Enter 10 – then press forward (top right) to jump to the next field item to enter the 0 and so on…….. when done press outgoing.

 

To program the phone with DHCP Disabled on the LAN

 

Programme or Default   Press 1

Static IP address:        10.0.0.20. 10.0.0.28

Subnet:                       255.255.255.0

Gateway:                     10.0.0.2

Remote IPC:                217.46.191.217

UDP                             leave as is

TCP:                             leave as is

Password:                     leave as is

TPTF                            leave as is

Enable DHCP:               No 

Vlan                              leave as is

PC Port                        leave as is

Save Changes               Press 1

 

To program the phone with DHCP Enabled on the LAN

 

Programme or Default   Press 1

Static IP address:         leave as is

Subnet:                        leave as is

Gateway:                     leave as is

Remote IPC:                217.46.191.217

UDP                             leave as is

TCP:                             leave as is

Password:                    leave as is

TPTF                            leave as is

Enable DHCP:               Yes

Vlan                              leave as is

PC Port                        leave as is

Save Changes               Press 1